How to replace a
thermocouple:
The
thermocouple is a gas furnace component located near the pilot light
burner. It is a safety device that shuts off the gas if the pilot light
goes out or the electric igniter fails.
If the pilot light won't stay lit, the thermocouple
may be faulty and should be adjusted or replaced. To adjust the
thermocouple, you must tighten the thermocouple nut with a wrench. Take
care not to apply too much pressure to the nut -- just tighten it
slightly. Then try lighting the pilot. If the pilot won't stay lit,
replace the thermocouple with a new one of the same type. Here's how to
replace a thermocouple:
Step 1: Unscrew
copper lead and connection nut inside threaded connection to gas line.
Under mounting bracket at thermocouple tube, unscrew bracket nut that
holds tube in place.
Step 2: Insert new thermocouple into hole in bracket. Be sure steel tube
is up and copper lead is down. Under bracket, screw bracket nut over
tube. Push connection nut to threaded connection where copper lead
connects to gas line. Make sure connection is clean and dry.
Step 3: Tightly screw nut into place, but do not over-tighten. Both
bracket nut and connection nut should be only a little tighter than if
hand-tightened.
Water
Heaters
The thermocouple
is a safety feature in gas
water heaters which determines if the
pilot light is lit. The heat of the pilot light flame creates millivolt
current in the thermocouple which energizes a magnet that in turn allows
the gas control valve to operate. If the pilot light goes out, the
thermocouple produces no power and the magnet closes the valve and will
not allow the gas to flow.
Caution: Please read our
safety information before attempting any
maintenance, installation or repair.
A common symptom of a faulty thermocouple is the pilot
light will not stay lit. Check that the thermocouple connection to the gas
valve is tight and the other end of the thermocouple is properly positioned
in or near the pilot light flame. If it appears properly installed then it
may need to be replaced.
-
Turn off the gas supply to water
heater
-
Remove outer and inner
doors.
-
Disconnect the burner assembly from the gas
control by loosening the pilot tube, supply tube and thermocouple
connections.
-
Remove burner assembly from the combustion
chamber.
-
Remove the old thermocouple from the bracket. It
may be held in place with tension or a screw. Loosen the screw, if any,
and pull firmly and twist the thermocouple from the bracket.
-
Install the new thermocouple. Position the
thermocouple tip so that the pilot flame heats the top 1/2 inch of the
tip.
-
Replace burner assembly in combustion chamber.
-
Tighten the main burner supply tube, pilot supply
tube and thermocouple connection to the gas control valve. Turn the
thermocouple no more than one quarter turn beyond hand tight.
-
Turn on the gas supply
-
Check main supply tube and pilot supply tube at
the gas control valve for gas leaks with a soap and water solution.
Bubbles indicate a leak. Tighten all connections if a leak is found.
-
Light the pilot light.
-
Check that 1/2 inch of the thermocouple tip is
positioned in the flame.
-
Replace inner and outer doors.
Replacing the thermocouple should restore power to
operate the gas valve and keep the flame going. If the problem
continues, the problem may be with the gas valve itself. If the gas
valve fails, due to its high cost, it may make sense to replace the
entire water heater, especially with older models.
.
|